570 kVA diesel generators.
Compare UK-designed and UK-manufactured 570 kVA diesel generator options and nearby ratings from Baudouin, Cummins, Perkins, Scania. Check the exact prime and standby output, engine and enclosure before selecting.
Options around 570 kVA.
A rounded GPS model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
Specify 570 kVA around your load.
Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.
At a power factor of 0.8, 570 kVA corresponds to 456 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleDoes a 570 kVA model deliver 570 kVA continuously?
The model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Can I get a canopied 570 kVA generator?
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with GenPro.
Which engine brands are available at this output?
The comparison above includes Baudouin, Cummins, Perkins, Scania. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
Electrical output comparison
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| GPS570SS | Scania | Acoustic canopied | 520 kVA | 571 kVA | 400 V |
| GPS570S | Scania | Open set | 520 kVA | 571 kVA | 400 V |
| GPS570CS | Cummins | Acoustic canopied | 507 kVA | 565 kVA | 400 V |
| GPS570C | Cummins | Open set | 507 kVA | 565 kVA | 400 V |
| GPS560PS | Perkins | Acoustic canopied | 513 kVA | 562 kVA | 400 V |
| GPS560P | Perkins | Open set | 513 kVA | 562 kVA | 400 V |
| GPS560CS | Cummins | Acoustic canopied | 503 kVA | 561 kVA | 400 V |
| GPS560C | Cummins | Open set | 503 kVA | 561 kVA | 400 V |
| GPS620SS | Scania | Acoustic canopied | 561 kVA | 617 kVA | 400 V |
| GPS620S | Scania | Open set | 561 kVA | 617 kVA | 400 V |
| GPS560BS | Baudouin | Acoustic canopied | 514 kVA | 559 kVA | 400 V |
| GPS560B | Baudouin | Open set | 514 kVA | 559 kVA | 400 V |
| GPS580CS | Cummins | Acoustic canopied | 529 kVA | 581 kVA | 400 V |
| GPS580C | Cummins | Open set | 529 kVA | 581 kVA | 400 V |
| GPS550BS | Baudouin | Acoustic canopied | 500 kVA | 550 kVA | 400 V |
| GPS550B | Baudouin | Open set | 500 kVA | 550 kVA | 400 V |




