600 kVA diesel generators.
Compare UK-designed and UK-manufactured 600 kVA diesel generator options and nearby ratings from Baudouin, Cummins, Perkins, Scania. Check the exact prime and standby output, engine and enclosure before selecting.
Options around 600 kVA.
A rounded GPS model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
Specify 600 kVA around your load.
Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.
At a power factor of 0.8, 600 kVA corresponds to 480 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleDoes a 600 kVA model deliver 600 kVA continuously?
The model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Can I get a canopied 600 kVA generator?
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with GenPro.
Which engine brands are available at this output?
The comparison above includes Baudouin, Cummins, Perkins, Scania. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
Electrical output comparison
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| GPS660PS | Perkins | Acoustic canopied | 600 kVA | 660 kVA | 400 V |
| GPS660P | Perkins | Open set | 600 kVA | 660 kVA | 400 V |
| GPS660SS | Scania | Acoustic canopied | 600 kVA | 660 kVA | 400 V |
| GPS660S | Scania | Open set | 600 kVA | 660 kVA | 400 V |
| GPS650BS | Baudouin | Acoustic canopied | 591 kVA | 647 kVA | 400 V |
| GPS650B | Baudouin | Open set | 591 kVA | 647 kVA | 400 V |
| GPS670PS | Perkins | Acoustic canopied | 610 kVA | 665 kVA | 400 V |
| GPS670P | Perkins | Open set | 610 kVA | 665 kVA | 400 V |
| GPS670SS | Scania | Acoustic canopied | 613 kVA | 674 kVA | 400 V |
| GPS680SS | Scania | Acoustic canopied | 613 kVA | 673 kVA | 400 V |
| GPS670S | Scania | Open set | 613 kVA | 674 kVA | 400 V |
| GPS680S | Scania | Open set | 613 kVA | 673 kVA | 400 V |
| GPS620SS | Scania | Acoustic canopied | 561 kVA | 617 kVA | 400 V |
| GPS620S | Scania | Open set | 561 kVA | 617 kVA | 400 V |
| GPS580CS | Cummins | Acoustic canopied | 529 kVA | 581 kVA | 400 V |
| GPS580C | Cummins | Open set | 529 kVA | 581 kVA | 400 V |