A model-specific render and installation drawing will be supplied with the quotation.
Designed and manufacturedin the United KingdomScania / Open set / 50 Hz
620 kVA class
Scania diesel generator
Open set generator with a DC16093A-02-52 engine and Stamford HCI544E1 reference alternator. Open sets require a suitable installation with ventilation, exhaust and weather protection.
Exact ratings above: 400 V, 3-phase, 50 Hz reference configuration. The model number is a rounded class.
Price and lead time confirmed with your quotation.
Technical specification.
| GenPro model | GPS620S |
|---|---|
| Engine brand / model | Scania DC16093A-02-52 |
| Alternator | Stamford HCI544E1 |
| Frequency | 50 Hz |
| Reference voltage | 400 V |
| Reference phase | 3 phase |
| Exact prime rating | 561 kVA / 449 kW |
| Exact standby rating | 617 kVA / 494 kW |
| Aspiration | Turbocharged |
|---|---|
| Governor | ECU |
| No. of Cylinders | 8 |
| Cylinder Arrangement | At Vee |
| Displacement | 16.4L |
| Cooling Type | Liquid Cooled |
| Coolant Capacity | 68L |
| Oil Capacity | 48L |
| Type | Brushless |
| Poles | 4 |
| AVR Model | AS440 |
| Voltage Regulation | 1% |
| Insulation Class | H |
| Excitation | Self Excited |
Voltage-specific ratings
Ratings for the reference engine and alternator configuration. Confirm the required connection and voltage with your quotation.
| Voltage | ESP kVA | ESP kW | PRP kVA | PRP kW |
|---|---|---|---|---|
| 190 V | 615 kVA | 492 kW | 561 kVA | 449 kW |
| 200 V | 617 kVA | 494 kW | 561 kVA | 449 kW |
| 208 V | 618 kVA | 494 kW | 562 kVA | 450 kW |
| 220 V | 619 kVA | 495 kW | 563 kVA | 450 kW |
| 220 V | 615 kVA | 492 kW | 560 kVA | 448 kW |
| 230 V | 617 kVA | 494 kW | 561 kVA | 449 kW |
| 240 V | 618 kVA | 494 kW | 562 kVA | 450 kW |
| 254 V | 619 kVA | 495 kW | 563 kVA | 450 kW |
| 380 V | 615 kVA | 492 kW | 560 kVA | 448 kW |
| 400 V | 617 kVA | 494 kW | 561 kVA | 449 kW |
| 415 V | 618 kVA | 494 kW | 562 kVA | 450 kW |
| 440 V | 619 kVA | 495 kW | 563 kVA | 450 kW |
Configuration options.
These documented electrical combinations sit within this rounded model family. Final enclosure and component selection are agreed with your quotation.
| Engine | Alternator | Phase | Voltage | Prime / PRP | Standby / ESP |
|---|---|---|---|---|---|
| DC16093A-02-52 | Stamford HCI544E1 | 3 | 400 V | 561 kVA | 617 kVA |
| DC16093A-02-52 | Stamford S5L1D-E41 | 3 | 400 V | 561 kVA | 617 kVA |
Installation & enclosure
| Reference weight | 3416.8 kg |
|---|---|
| Reference fuel tank | 730 litres |
| Configuration market | Export |
Dimensions and weight relate to the stated reference build, not every option. Acoustic figures, where listed, are manufacturer references at 75% rated kW using distance corrections. Confirm the project noise requirement and final drawing before installation.
Fuel consumption
| 50% Load | 55.7 litres/hour |
|---|---|
| 75% Load | 81.5 litres/hour |
| 100% Load | 108.6 litres/hour |
| 110% Load | 122.1 litres/hour |
Manufacturer reference consumption. Actual fuel use depends on load, operating conditions and the final specification.