550 kVA diesel generators.
Compare UK-designed and UK-manufactured 550 kVA diesel generator options and nearby ratings from Baudouin, Cummins, Perkins, Scania. Check the exact prime and standby output, engine and enclosure before selecting.
Options around 550 kVA.
A rounded GPS model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
550 kVA class
Scania generator
DC16071A-02-02
550 kVA class
Scania generator
DC16071A-02-02
Specify 550 kVA around your load.
Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.
At a power factor of 0.8, 550 kVA corresponds to 440 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleDoes a 550 kVA model deliver 550 kVA continuously?
The model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Can I get a canopied 550 kVA generator?
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with GenPro.
Which engine brands are available at this output?
The comparison above includes Baudouin, Cummins, Perkins, Scania. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
Electrical output comparison
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| GPS550BS | Baudouin | Acoustic canopied | 500 kVA | 550 kVA | 400 V |
| GPS550B | Baudouin | Open set | 500 kVA | 550 kVA | 400 V |
| GPS550CS | Cummins | Acoustic canopied | 500 kVA | 550 kVA | 400 V |
| GPS550C | Cummins | Open set | 500 kVA | 550 kVA | 400 V |
| GPS550PS | Perkins | Acoustic canopied | 500 kVA | 550 kVA | 400 V |
| GPS550P | Perkins | Open set | 500 kVA | 550 kVA | 400 V |
| GPS550SS | Scania | Acoustic canopied | 550 kVA | Confirm on enquiry | 400 V |
| GPS550S | Scania | Open set | 550 kVA | Confirm on enquiry | 400 V |
| GPS560BS | Baudouin | Acoustic canopied | 514 kVA | 559 kVA | 400 V |
| GPS560B | Baudouin | Open set | 514 kVA | 559 kVA | 400 V |
| GPS560CS | Cummins | Acoustic canopied | 503 kVA | 561 kVA | 400 V |
| GPS560C | Cummins | Open set | 503 kVA | 561 kVA | 400 V |
| GPS620SS | Scania | Acoustic canopied | 561 kVA | 617 kVA | 400 V |
| GPS620S | Scania | Open set | 561 kVA | 617 kVA | 400 V |
| GPS560PS | Perkins | Acoustic canopied | 513 kVA | 562 kVA | 400 V |
| GPS560P | Perkins | Open set | 513 kVA | 562 kVA | 400 V |