900 kVA diesel generators.
Compare UK-designed and UK-manufactured 900 kVA diesel generator options and nearby ratings from Baudouin, Cummins, Perkins. Check the exact prime and standby output, engine and enclosure before selecting.
Options around 900 kVA.
A rounded GPS model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
1,000 kVA class
Baudouin generator
12M26G1000/5
1,000 kVA class
Baudouin generator
12M26G1000/5
Specify 900 kVA around your load.
Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.
At a power factor of 0.8, 900 kVA corresponds to 720 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleDoes a 900 kVA model deliver 900 kVA continuously?
The model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Can I get a canopied 900 kVA generator?
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with GenPro.
Which engine brands are available at this output?
The comparison above includes Baudouin, Cummins, Perkins. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
Electrical output comparison
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| GPS900BS | Baudouin | Acoustic canopied | 820 kVA | 904 kVA | 400 V |
| GPS900B | Baudouin | Open set | 820 kVA | 904 kVA | 400 V |
| GPS900PS | Perkins | Acoustic canopied | 802 kVA | 896 kVA | 400 V |
| GPS900P | Perkins | Open set | 802 kVA | 896 kVA | 400 V |
| GPS910BS | Baudouin | Acoustic canopied | 828 kVA | 907 kVA | 400 V |
| GPS910B | Baudouin | Open set | 828 kVA | 907 kVA | 400 V |
| GPS890PS | Perkins | Acoustic canopied | 799 kVA | 893 kVA | 400 V |
| GPS890P | Perkins | Open set | 799 kVA | 893 kVA | 400 V |
| GPS1000PS | Perkins | Acoustic canopied | 911 kVA | 1000 kVA | 400 V |
| GPS1000P | Perkins | Open set | 911 kVA | 1000 kVA | 400 V |
| GPS880CS | Cummins | Acoustic canopied | 812 kVA | 880 kVA | 400 V |
| GPS880C | Cummins | Open set | 812 kVA | 880 kVA | 400 V |
| GPS1000CS | Cummins | Acoustic canopied | 931 kVA | 1010 kVA | 400 V |
| GPS1000C | Cummins | Open set | 931 kVA | 1010 kVA | 400 V |
| GPS1000BS | Baudouin | Acoustic canopied | 940 kVA | 1010 kVA | 400 V |
| GPS1000B | Baudouin | Open set | 940 kVA | 1010 kVA | 400 V |