880 kVA diesel generators.
Compare UK-designed and UK-manufactured 880 kVA diesel generator options and nearby ratings from Baudouin, Cummins, Perkins. Check the exact prime and standby output, engine and enclosure before selecting.
Options around 880 kVA.
A rounded GPS model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
Specify 880 kVA around your load.
Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.
At a power factor of 0.8, 880 kVA corresponds to 704 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleDoes a 880 kVA model deliver 880 kVA continuously?
The model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Can I get a canopied 880 kVA generator?
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with GenPro.
Which engine brands are available at this output?
The comparison above includes Baudouin, Cummins, Perkins. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
Electrical output comparison
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| GPS880CS | Cummins | Acoustic canopied | 812 kVA | 880 kVA | 400 V |
| GPS880C | Cummins | Open set | 812 kVA | 880 kVA | 400 V |
| GPS890PS | Perkins | Acoustic canopied | 799 kVA | 893 kVA | 400 V |
| GPS890P | Perkins | Open set | 799 kVA | 893 kVA | 400 V |
| GPS900PS | Perkins | Acoustic canopied | 802 kVA | 896 kVA | 400 V |
| GPS900P | Perkins | Open set | 802 kVA | 896 kVA | 400 V |
| GPS860PS | Perkins | Acoustic canopied | 797 kVA | 860 kVA | 400 V |
| GPS860P | Perkins | Open set | 797 kVA | 860 kVA | 400 V |
| GPS900BS | Baudouin | Acoustic canopied | 820 kVA | 904 kVA | 400 V |
| GPS900B | Baudouin | Open set | 820 kVA | 904 kVA | 400 V |
| GPS910BS | Baudouin | Acoustic canopied | 828 kVA | 907 kVA | 400 V |
| GPS910B | Baudouin | Open set | 828 kVA | 907 kVA | 400 V |
| GPS1000PS | Perkins | Acoustic canopied | 911 kVA | 1000 kVA | 400 V |
| GPS1000P | Perkins | Open set | 911 kVA | 1000 kVA | 400 V |
| GPS850PS | Perkins | Acoustic canopied | 767 kVA | 846 kVA | 400 V |
| GPS850P | Perkins | Open set | 767 kVA | 846 kVA | 400 V |