Compare UK-designed and UK-manufactured 1,850 kVA diesel generator options and nearby ratings from Baudouin, Cummins, Perkins. Check the exact prime and standby output, engine and enclosure before selecting.
A rounded GPS model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
4016-61TRG1
4012-46TAG3A
4012-46TAG3A
QSK60G3 HPI
4012-46TAG3A
4012-46TAG3A
16M33G2000/5
16M33G2000/5
16M33G1900/5
16M33G1900/5
High-capacity installations need a complete engineering review of load behaviour, cooling, exhaust, fuel storage, switching and service access. Confirm the installation drawing and rated operating conditions before procurement.
At a power factor of 0.8, 1,850 kVA corresponds to 1480 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleThe model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with GenPro.
The comparison above includes Baudouin, Cummins, Perkins. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| GPS2000PS | Perkins | Acoustic canopied | 1866 kVA | 2012 kVA | 400 V |
| GPS2000P | Perkins | Open set | 1866 kVA | 2012 kVA | 400 V |
| GPS1850PS | Perkins | Acoustic canopied | 1728 kVA | 1873 kVA | 400 V |
| GPS1850P | Perkins | Open set | 1728 kVA | 1873 kVA | 400 V |
| GPS2050CS | Cummins | Acoustic canopied | 1876 kVA | 2061 kVA | 400 V |
| GPS2050C | Cummins | Open set | 1876 kVA | 2061 kVA | 400 V |
| GPS1800CS | Cummins | Acoustic canopied | 1647 kVA | 1818 kVA | 400 V |
| GPS1800C | Cummins | Open set | 1647 kVA | 1818 kVA | 400 V |
| GPS1900PS | Perkins | Acoustic canopied | 1729 kVA | 1897 kVA | 400 V |
| GPS1900P | Perkins | Open set | 1729 kVA | 1897 kVA | 400 V |
| GPS2050BS | Baudouin | Acoustic canopied | 1900 kVA | 2035 kVA | 400 V |
| GPS2050B | Baudouin | Open set | 1900 kVA | 2035 kVA | 400 V |
| GPS1900BS | Baudouin | Acoustic canopied | 1746 kVA | 1922 kVA | 400 V |
| GPS1900B | Baudouin | Open set | 1746 kVA | 1922 kVA | 400 V |
Tell us your load, site and application. We’ll help you choose the right configuration.