GENPRO / UK DESIGNED & MANUFACTURED GENERATORS+44 (0)121 517 0315
Generator power guide

680 kVA diesel generators.

Compare UK-designed and UK-manufactured 680 kVA diesel generator options and nearby ratings from Cummins, Perkins, Scania. Check the exact prime and standby output, engine and enclosure before selecting.

Compare exact outputs

Options around 680 kVA.

A rounded GPS model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.

Industrial and infrastructure projects

Specify 680 kVA around your load.

Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.

At a power factor of 0.8, 680 kVA corresponds to 544 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.

Discuss your load schedule
Does a 680 kVA model deliver 680 kVA continuously?

The model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.

Can I get a canopied 680 kVA generator?

Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with GenPro.

Which engine brands are available at this output?

The comparison above includes Cummins, Perkins, Scania. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.

Electrical output comparison

ModelEngine brandFormatPrimeStandbyVoltage
GPS670SSScaniaAcoustic canopied613 kVA674 kVA400 V
GPS670SScaniaOpen set613 kVA674 kVA400 V
GPS680SSScaniaAcoustic canopied613 kVA673 kVA400 V
GPS680SScaniaOpen set613 kVA673 kVA400 V
GPS720PSPerkinsAcoustic canopied670 kVA721 kVA400 V
GPS720PPerkinsOpen set670 kVA720 kVA400 V
GPS700CSCumminsAcoustic canopied640 kVA691 kVA400 V
GPS700CCumminsOpen set640 kVA691 kVA400 V
GPS690CSCumminsAcoustic canopied640 kVA692 kVA400 V
GPS690CCumminsOpen set640 kVA692 kVA400 V
GPS670PSPerkinsAcoustic canopied610 kVA665 kVA400 V
GPS670PPerkinsOpen set610 kVA665 kVA400 V
GPS660PSPerkinsAcoustic canopied600 kVA660 kVA400 V
GPS770PSPerkinsAcoustic canopied700 kVA770 kVA400 V
GPS660PPerkinsOpen set600 kVA660 kVA400 V
GPS770PPerkinsOpen set700 kVA770 kVA400 V

Let’s specify your next generator.

Tell us your load, site and application. We’ll help you choose the right configuration.

Talk to GenPro
Call GenProRequest a quote