1,650 kVA class
Perkins generator
4012-46TAG2A

Representative generator image; final appearance follows the confirmed build specification.
Designed and manufacturedOpen set generator with a 4012-46TAG2A engine and Stamford S7L1D-C41 reference alternator. Open sets require a suitable installation with ventilation, exhaust and weather protection.
Exact ratings above: 400 V, 3-phase, 50 Hz reference configuration. The model number is a rounded class.
Price and lead time confirmed with your quotation.
| GenPro model | GPS1650P |
|---|---|
| Engine brand / model | Perkins 4012-46TAG2A |
| Alternator | Stamford S7L1D-C41 |
| Frequency | 50 Hz |
| Reference voltage | 400 V |
| Reference phase | 3 phase |
| Exact prime rating | 1511 kVA / 1209 kW |
| Exact standby rating | 1660 kVA / 1328 kW |
| Aspiration | Turbocharged |
|---|---|
| Governor | Electronic |
| No. of Cylinders | 12 |
| Cylinder Arrangement | At Vee |
| Displacement | 45.84L |
| Cooling Type | Liquid Cooled |
| Coolant Capacity | 223L |
| Oil Capacity | 157.5L |
| Type | Brushless |
| Poles | 4 |
| AVR Model | MX341 |
| Voltage Regulation | 1% |
| Insulation Class | H |
| Excitation | PMG |
Ratings for the reference engine and alternator configuration. Confirm the required connection and voltage with your quotation.
| Voltage | ESP kVA | ESP kW | PRP kVA | PRP kW |
|---|---|---|---|---|
| 380 V | 1615 kVA | 1292 kW | 1505 kVA | 1204 kW |
| 400 V | 1660 kVA | 1328 kW | 1511 kVA | 1209 kW |
These documented electrical combinations sit within this rounded model family. Final enclosure and component selection are agreed with your quotation.
| Engine | Alternator | Phase | Voltage | Prime / PRP | Standby / ESP |
|---|---|---|---|---|---|
| 4012-46TAG2A | Stamford S7L1D-C41 | 3 | 400 V | 1511 kVA | 1660 kVA |
| 4012-46TAG2A | Leroy Somer LSA50.2L8 | 3 | 400 V | 1500 kVA | 1650 kVA |
| Dimensions (L × W × H) | 4969 × 2200 × 2504 mm |
|---|---|
| Reference weight | 9822.5 kg |
| Configuration market | Export |
Dimensions and weight relate to the stated reference build, not every option. Acoustic figures, where listed, are manufacturer references at 75% rated kW using distance corrections. Confirm the project noise requirement and final drawing before installation.
| 50% Load | 161.5 litres/hour |
|---|---|
| 75% Load | 238.7 litres/hour |
| 100% Load | 313.5 litres/hour |
| 110% Load | 348.6 litres/hour |
Manufacturer reference consumption. Actual fuel use depends on load, operating conditions and the final specification.
4012-46TAG2A
4012-46TWG3A
4012-46TWG3A
Tell us your load, site and application. We’ll help you choose the right configuration.