1,550 kVA class
Baudouin generator
12M33G1500/5
A model-specific render and installation drawing will be supplied with the quotation.
Designed and manufacturedAcoustic canopied generator with a 12M33G1500/5 engine and Stamford S7L1D-C41 reference alternator. Acoustic canopy and sound requirements to be confirmed for your application.
Exact ratings above: 400 V, 3-phase, 50 Hz reference configuration. The model number is a rounded class.
Price and lead time confirmed with your quotation.
| GenPro model | GPS1550BS |
|---|---|
| Engine brand / model | Baudouin 12M33G1500/5 |
| Alternator | Stamford S7L1D-C41 |
| Frequency | 50 Hz |
| Reference voltage | 400 V |
| Reference phase | 3 phase |
| Exact prime rating | 1389 kVA / 1111 kW |
| Exact standby rating | 1529 kVA / 1223 kW |
| Aspiration | Turbocharged |
|---|---|
| Governor | Electronic |
| No. of Cylinders | 12 |
| Cylinder Arrangement | At Vee |
| Displacement | 39.2L |
| Cooling Type | Liquid Cooled |
| Coolant Capacity | 188L |
| Oil Capacity | 160L |
| Type | Brushless |
| Poles | 4 |
| AVR Model | MX341 |
| Voltage Regulation | 1% |
| Insulation Class | H |
| Excitation | PMG |
Ratings for the reference engine and alternator configuration. Confirm the required connection and voltage with your quotation.
| Voltage | ESP kVA | ESP kW | PRP kVA | PRP kW |
|---|---|---|---|---|
| 380 V | 1528 kVA | 1222 kW | 1388 kVA | 1110 kW |
| 400 V | 1529 kVA | 1223 kW | 1389 kVA | 1111 kW |
These documented electrical combinations sit within this rounded model family. Final enclosure and component selection are agreed with your quotation.
| Engine | Alternator | Phase | Voltage | Prime / PRP | Standby / ESP |
|---|---|---|---|---|---|
| 12M33G1500/5 | Stamford S7L1D-C41 | 3 | 400 V | 1389 kVA | 1529 kVA |
| Dimensions, weight and fuel tank | Confirmed with quotation and build drawing |
|---|
Dimensions and weight relate to the stated reference build, not every option. Acoustic figures, where listed, are manufacturer references at 75% rated kW using distance corrections. Confirm the project noise requirement and final drawing before installation.
| 50% Load | 146.2 litres/hour |
|---|---|
| 75% Load | 214.4 litres/hour |
| 100% Load | 296.9 litres/hour |
| 110% Load | 330.5 litres/hour |
Manufacturer reference consumption. Actual fuel use depends on load, operating conditions and the final specification.
12M33G1500/5
12M33G1650/5
12M33G1650/5
Tell us your load, site and application. We’ll help you choose the right configuration.