A model-specific render and installation drawing will be supplied with the quotation.
Designed and manufacturedin the United KingdomPerkins / Open set / 50 Hz
410 kVA class
Perkins diesel generator
Open set generator with a 2206A-E13TAG2 engine and Leroy Somer TAL0473B reference alternator. Open sets require a suitable installation with ventilation, exhaust and weather protection.
Exact ratings above: 400 V, 3-phase, 50 Hz reference configuration. The model number is a rounded class.
Price and lead time confirmed with your quotation.
Technical specification.
| GenPro model | GPS410P |
|---|---|
| Engine brand / model | Perkins 2206A-E13TAG2 |
| Alternator | Leroy Somer TAL0473B |
| Frequency | 50 Hz |
| Reference voltage | 400 V |
| Reference phase | 3 phase |
| Exact prime rating | 361 kVA / 289 kW |
| Exact standby rating | 412 kVA / 330 kW |
| Aspiration | Turbocharged |
|---|---|
| Governor | Electronic |
| No. of Cylinders | 6 |
| Cylinder Arrangement | In Line |
| Displacement | 12.5L |
| Cooling Type | Liquid Cooled |
| Coolant Capacity | 51.4L |
| Oil Capacity | 40.0L |
| Type | Brushless |
| Poles | 4 |
| AVR Model | R150 |
| Voltage Regulation | 1.0% Regulation% |
| Insulation Class | H |
| Excitation | Brushless |
Voltage-specific ratings
Ratings for the reference engine and alternator configuration. Confirm the required connection and voltage with your quotation.
| Voltage | ESP kVA | ESP kW | PRP kVA | PRP kW |
|---|---|---|---|---|
| 400 V | 412 kVA | 330 kW | 361 kVA | 289 kW |
Configuration options.
These documented electrical combinations sit within this rounded model family. Final enclosure and component selection are agreed with your quotation.
| Engine | Alternator | Phase | Voltage | Prime / PRP | Standby / ESP |
|---|---|---|---|---|---|
| 2206A-E13TAG2 | Leroy Somer TAL0473B | 3 | 400 V | 361 kVA | 412 kVA |
| 2206A-E13TAG2 | Leroy Somer TAL0473A | 3 | 400 V | 356 kVA | 405 kVA |
Installation & enclosure
| Dimensions (L × W × H) | 3075 × 1180 × 2057 mm |
|---|---|
| Reference weight | 3148.1 kg |
| Reference fuel tank | 730 litres |
| Configuration market | Export |
Dimensions and weight relate to the stated reference build, not every option. Acoustic figures, where listed, are manufacturer references at 75% rated kW using distance corrections. Confirm the project noise requirement and final drawing before installation.
Fuel consumption
| 50% Load | 37 litres/hour |
|---|---|
| 75% Load | 54 litres/hour |
| 100% Load | 71 litres/hour |
| 110% Load | 80 litres/hour |
Manufacturer reference consumption. Actual fuel use depends on load, operating conditions and the final specification.