Perkins CKD Generator Packages

3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 403D-11G

    Alternator: Mecc Alte

    Model: ECP3-1L

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 403D-15G

    Alternator: Mecc Alte

    Model: ECP28-OS/4 OR ECP3-2L

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 403A-15G2

    Alternator: Mecc Alte

    Model: ECP3-3L

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 404D-22G

    Alternator: Mecc Alte

    Model: ECP28-M4

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1103A-33G

    Alternator: Mecc Alte

    Model: ECP28-VL

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1103A-33TG1

    Alternator: Mecc Alte

    Model: ECP32-2S

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1103A-33TG2

    Alternator: Mecc Alte

    Model: ECP32-2M

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1104A-44TG1

    Alternator: Leroy Somer

    Model: TAL044A

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1104A-44TG2

    Alternator: Leroy Somer

    Model: TAL044B

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1104C-44TAG2

    Alternator: Leroy Somer

    Model: TAL044D

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1106A-70TG1

    Alternator: Leroy Somer

    Model: TAL044H

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1106A-70TAG2

    Alternator: Leroy Somer

    Model: TAL044J

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1106A-70TAG2

    Alternator: Leroy Somer

    Model: TAL044J

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1106A-70TAG3

    Alternator: Leroy Somer

    Model: TAL044L

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1106A-70TAG4

    Alternator: Leroy Somer

    Model: TAL044M

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1206A-E70TTAG2

    Alternator: Leroy Somer

    Model: TAL046C

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1206A-E70TTAG3

    Alternator: Leroy Somer

    Model: TAL046D

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1506A-E88TAG4

    Alternator: Leroy Somer

    Model: TAL046E

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 1706A-E93TAG2

    Alternator: Leroy Somer

    Model: TAL046H

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 2206A-E13TAG3

    Alternator: Leroy Somer

    Model: TAL0473A

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 2506A-E15TAG1

    Alternator: Leroy Somer

    Model: TAL0473B

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 2506A-E15TAG1

    Alternator: Leroy Somer

    Model: TAL0473B

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 2506A-E15TAG2

    Alternator: Leroy Somer

    Model: TAL0473C

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 2806A-E18TAG1

    Alternator: Leroy Somer

    Model: TAL0473E

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 2806A-E18TAG2

    Alternator: Leroy Somer

    Model: TAL0473F

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 2806A-E18TTAG4

    Alternator: Leroy Somer

    Model: TAL049B

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 2806A-E18TTAG5

    Alternator: Leroy Somer

    Model: TAL049C

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4006-23TAG2A

    Alternator: Leroy Somer

    Model: TAL049C

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4006-23TAG3A

    Alternator: Leroy Somer

    Model: TAL049C

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4008TAG1A

    Alternator: Leroy Somer

    Model: TAL049D

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4008TAG2A

    Alternator: Leroy Somer

    Model: TAL049E

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4008-30TAG3

    Alternator: Leroy Somer

    Model: LSA50.2M6

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4012-46TWG2A

    Alternator: Leroy Somer

    Model: LSA50.2M6

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4012-46TWG3A

    Alternator: Leroy Somer

    Model: LSA50.2L7

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4012-46TWG3A

    Alternator: Leroy Somer

    Model: LSA50.2L7

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4012-46TAG3A

    Alternator: Leroy Somer

    Model: LSA52.3S5

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4016-61TRG1

    Alternator: Leroy Somer

    Model: LSA52.3S5

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4016-61TRG2

    Alternator: Leroy Somer

    Model: LSA52.3S6

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

  • Engine: Perkins Electropack

    Model: 4016-61TRG3

    Alternator: Leroy Somer

    Model: LSA52.3L9

    Configuration: 3 Phase | 400V | 1500RPM | 50Hz | PF 0.8

At GenPro Generators, we also specialise in providing CKD Generator Packages (Completely Knocked Down) generators, offering versatility and cost-saving benefits.

Why Choose GenPro Generator for CKD?

  • Ensure Approval: Rest assured knowing that our supply is approved by both the engine and alternator manufacturer.

  • Comprehensive Offering: We offer the only hypermarket in the world catering to the generating set industry.

  • Extensive Inventory: With over 9,000 engines and alternators ranging from 9-2250 kVA readily available in stock, we ensure immediate delivery in large quantities.

  • Customization: Tailor your generating set to exact customer requirements, incorporating your brand identity and creativity to promote your own brand.

  • Total Control: Maintain full control over the cost, quality, and profitability of your generating set.

  • Cost Efficiency: Benefit from significant reductions in import duty and transport costs.

  • Swift Delivery: Enjoy immediate delivery of the two most crucial components of your generating set.

  • Competitive Pricing: Our prices are highly competitive in the market, offering exceptional value when comparing like-for-like products.

  • Diverse Options: Choose from a wide variety of top brands for generating set manufacturers.

  • Flexibility: Experience high flexibility in supply arrangements to meet your specific needs.

    Benefits of CKD Generators:

  • CKD Generators are Shipped as unassembled parts.

  • Lower import taxes: Enjoy reduced taxes compared to fully assembled generators.

  • Smaller capital investment: Reduce upfront costs by purchasing parts instead of investing in vertical integration.

  • Lower transportation costs: Save on shipping expenses due to compact parts packaging.

  • Lower assembly expenses: Eliminate labor markups and reduce overall assembly costs.

  • Enhanced assembly quality: Ensure precise assembly and avoid costly errors.

  • Compliance with Local Regulations: Meet stringent regulations by assembling generators locally.

  • Improved productivity: Streamline processes and boost assembly worker efficiency.

  • Increased competitiveness: Lower costs per unit and pass on savings to customers, enhancing competitiveness.

  • Expand supply and demand:** Increase business volume while maintaining profit margins.

At GenPro Generators, we offer a comprehensive selection of CKD generator solutions tailored to your requirements:

Our packages include renowned British PERKINS CKD - LISTER PETTER CKD - CUMMINS CKD - VOLVE CKD - Engines coupled to European Leroy Somer alternators

Control Systems: Deepsea control panel 7320 Mk II AMF Control Module (supplied lose)

Contact Information:

  • Phone: +44 (0)121 238 1606

  • Mobile: +44 (0)7853 092 761

  • Email: info@genprogenerators.co.uk

  • Web: www.genprogenerators.co.uk